2.4.1 System Wiring
The connection and wiring procedure for C-BOX 200 is described as follows:
1) Open the C-BOX 200 as described in paragraph 2.2.
2) Verify that the C-BOX 200 power switch is off (see Figure 8).
3) Unscrew the compression connectors and pass all the system cables
through them into the C-BOX 200 housing.
4) To connect the power and input/output signals:
Prepare the individual wires of the system cables by stripping the
insulation back approximately 1 cm.
Using a device such as a screwdriver, push down on the lever directly
next to the clamp (see Figure 7).
Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
Figure 7 - System Cable Connections
The wiring used can be solid or stranded but must meet the following specifications.
All positions: 24 - 16 AWG 0.2 - 1.5 mm²