INSTALLATION
2
2.6.2 2000N Family Scanners
For 2000N scanner families which operate in an ID-NET™ network configuration, a
typical layout is shown below and the C-BOX 150/100s are connected as follows.
Figure 18 – Typical ID-NET™ scanner Layout
C-BOX 150 can perform Backup/Restore of a whole cluster under the following
conditions:
the Master/Slave network is composed of one master and up to 9
Slaves maximum
the Master/Slave network must be either Synchronized or Multidata
In order to perform Backup/Restore of Master only, the C-BOX 150 Cluster
GET/SEND parameter must be configured to "Master only", see the WinHost Help
On-Line.