Datalogic Scanning F732 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach PC / Workstation Barebones Datalogic Scanning F732 herunter. Datalogic Scanning F732 User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - F732 WIZARD™

F732 WIZARD™User’s Manual

Seite 2

F732 WIZARD™14Ed.: 06/01EasyGen™ Application GeneratorBy using the EasyGen™ software, developers can easilyand quickly build personalized applications

Seite 3

GENERAL INFORMATION1Ed.: 06/0151.5 CONTENTS OF PACKINGThe F732 terminal package includes:− nr. 1 F732 terminal complete with batteries;− nr. 1 crad

Seite 4

F732 WIZARD™16Ed.: 06/011.6 TERMINAL IDENTIFICATIONSER 123456789 COD 941404020 MOD F732/B 128K Datalo gic SpA 00/0 1CAUTI ONSER 123

Seite 5 - CONTENTS

SAFETY REGULATIONS2Ed.: 06/0172 SAFETY REGULATIONSNOTERead this manual carefully beforeperforming any type of connection or repairon the F732 terminal

Seite 6

F732 WIZARD™28Ed.: 06/012.2 LASER SAFETYThe laser light is visible to the human eye and is emittedfrom the window indicated in the figure.SER 12345678

Seite 7 - 1 GENERAL INFORMATION

SAFETY REGULATIONS2Ed.: 06/019IDFELUCE LASERNON FISSAREIL FASCIOAPPARECCHIOLASER DICLASSE 2MASSIMAPOTENZAD'USCITA:LUNGHEZZAD'ONDAEMESSA:CONF

Seite 8

F732 WIZARD™210Ed.: 06/01ITALIANOLe seguenti informazioni vengono fornite dietro direttivedelle autorità internazionali e si riferiscono all’uso corre

Seite 9 - GENERAL INFORMATION

SAFETY REGULATIONS2Ed.: 06/0111ACHTUNGJegliche Änderungen am Gerät sowieVorgehensweisen, die nicht in dieserBetriebsanleitung beschreiben werden,könne

Seite 10 - 1.4 PURPOSE OF THE MANUAL

F732 WIZARD™212Ed.: 06/01ESPAÑOLLas informaciones siguientes son presentadas enconformidad con las disposiciones de las autoridadesinternacionales y s

Seite 11 - 1.5 CONTENTS OF PACKING

SAFETY REGULATIONS2Ed.: 06/01132.3 FCC COMPLIANCE - INFORMATION FORTHE USERCAUTIONThis device complies with PART 15 of theFCC Rules. Operation is sub

Seite 12 - 1.6 TERMINAL IDENTIFICATION

F732 WIZARD™User’s Manual

Seite 13 - 2 SAFETY REGULATIONS

F732 WIZARD™314Ed.: 06/013 CONNECTION3.1 CRADLETo make the F732 terminal operative, it is necessary toinsert it in the Formula 952 Transceiver charger

Seite 14 - 2.2 LASER SAFETY

CONNECTION3Ed.: 06/0115The following figure describes the F952 cradle:ABPOWER +9VRS-2 32 PORTS/N 2019500252 Mod. F952 Code n. 140901450Datalogic Sp

Seite 15 - Ed.: 06/01

F732 WIZARD™316Ed.: 06/013.2 CONNECTION TO THE HOST COMPUTERCAUTIONBefore proceeding with this phase, makesure that both the computer and the F732ter

Seite 16 - ATTENZIONE

CONNECTION3Ed.: 06/0117Power Supply94A054000(94A054010)ABCKey:A) Host computerB) Single cradle F952C) Power supply

Seite 17

F732 WIZARD™318Ed.: 06/013.3 CONNECTION CABLESSeveral types of cables are available depending on the typeof computer and connection.The following cabl

Seite 18 - ATENCIÓN

USE AND OPERATION4Ed.: 06/01194 USE AND OPERATIONWhen an EasyGen™ application program is loaded ontothe F732 terminal (either a Demo example or an ap

Seite 19 - THE USER

F732 WIZARD™420Ed.: 06/014.1 LOADING APPLICATION PROGRAMSIf you are using application programs for EasyGen™ (seepar. 1.2 or par. 1.3) refer to chapte

Seite 20 - 3 CONNECTION

USE AND OPERATION4Ed.: 06/01214.3 DESCRIPTION OF KEYSAlthough EasyGen™ for Formula allows assigningcustomized functions to function keys, there are s

Seite 21 - Datalogic SpA 99/10

F732 WIZARD™422Ed.: 06/01ESC KEY: used in the “Data display”mode.SHIFT KEY: Enables the entry ofalphabetical characters (written inwhite on the keyboa

Seite 22 - 3.2.1 RS-232 Connection

USE AND OPERATION4Ed.: 06/0123BACKSPACE KEY: deletes the lastcharacter entered.SPACE KEY: allows the introduction ofa blank space. If the <SHIFT>

Seite 23 - 94A054010)

F732 WIZARD™USER'S MANUAL

Seite 24 - 3.3 CONNECTION CABLES

F732 WIZARD™424Ed.: 06/014.4 DOWNLOADING DATA TO HOSTData can be downloaded from the terminal to the host PC indifferent ways, depending on the appli

Seite 25 - 4 USE AND OPERATION

MAINTENANCE5Ed.: 06/01255 MAINTENANCENOTERechargeable battery packs (NiCd) are notinitially charged. Therefore the firstoperation to perform is to cha

Seite 26 - 4.2 BAR CODE SCANNING

F732 WIZARD™526Ed.: 06/01Recharging should be made after using the terminal untilthe batteries are nearly flat.ATTENTIONWhen the F732 terminal display

Seite 27 - 4.3 DESCRIPTION OF KEYS

MAINTENANCE5Ed.: 06/01275.2 REPLACING THE BATTERIESATTENTIONBefore proceeding, ensure that theterminal is switched off and that the datait contains h

Seite 28

F732 WIZARD™528Ed.: 06/013- Replace the batterypack, making sure thebatteries are inserted inthe right direction asindicated on the cover.4- Close th

Seite 29 - USE AND OPERATION

TROUBLESHOOTING6Ed.: 06/01296 TROUBLESHOOTINGPROBLEM CAUSE REMEDYFlat batteries. Rechargeterminal.When the<SCAN> buttonis pressed theterminal do

Seite 30 - 4.4 DOWNLOADING DATA TO HOST

F732 WIZARD™630Ed.: 06/01PROBLEM CAUSE REMEDYThe terminal willnot load theapplicationprogram.The terminalalready containsan applicationprogram.Followi

Seite 31 - 5 MAINTENANCE

TECHNICAL FEATURES7Ed.: 06/01317 TECHNICAL FEATURESOpticalLight source laser scanner, VLD source,670 nmScan rate 36 ± 3 scan/secMinimum resolution 0.1

Seite 32

F732 WIZARD™732Ed.: 06/01PhysicalTechnology SMT (Surface Mounting Technology)Dimensions (LxWxH) 165 x 56 x 32 mm(6.49 x 2.20 x 1.26 in)Weight 184 gr.

Seite 33 - 5.2 REPLACING THE BATTERIES

TECHNICAL FEATURES7Ed.: 06/0133ProgrammingOperating modes bootstrap loader applicationprogramTransmissionF952 interface via optical transceiver with s

Seite 34 - 5.3 CLEANING THE TERMINAL

DATALOGIC S.p.A.Via Candini 240012 - Lippo di Calderara di RenoBologna - ItalyFormula 732 Wizard™ - User's ManualEd.: 06/01ALL RIGHTS RESERVEDDat

Seite 35 - 6 TROUBLESHOOTING

F732 WIZARD™A34Ed.: 06/01A F732 PRODUCTS ANDACCESSORIES Formula 732 Terminals− Formula 732 Pocket Laser TerminalHand-held programmable laser micro-t

Seite 36

DATALOGIC S.p.A.,Via Candini, 240012 - Lippo di CalderaraBologna - Italydichiara chedeclares that thedéclare que lebescheinigt, daß das Gerätdeclare q

Seite 37 - 7 TECHNICAL FEATURES

iiiCONTENTS1 GENERAL INFORMATION... 11.1 F732 WIZARD™ Terminal Description... 11.2 Downloading EasyGen™

Seite 39 - TECHNICAL FEATURES

GENERAL INFORMATION1Ed.: 06/0111 GENERAL INFORMATION1.1 F732 WIZARD™ TERMINAL DESCRIPTIONFor vast majority of small businesses and retailers, thecomp

Seite 40 - ACCESSORIES

F732 WIZARD™12Ed.: 06/01The EasyGen™ Demo Version with five ready-to-useexample applications can be downloaded from theDatalogic web site free of char

Seite 41

GENERAL INFORMATION1Ed.: 06/013The F732 terminal has an LCD graphic display of 16characters by 4 lines plus a line in the upper part of thedisplay for

Kommentare zu diesen Handbüchern

Keine Kommentare