PowerScan® PD7100 CordedLinear Imaging Barcode ReaderProduct Reference Guide
Introduction2PowerScan® PD7100 CordedChapter 11, Symbologies defines options for all symbologies and provides the program-ming barcodes necessary for
IBM 46XX Interface92 PowerScan® PD7100 Corded46xx Number of Host Resets — cont.ENTER/EXIT PROGRAMMING MODE46xx Number of Host Resets = 1346xx Number o
Transmit Labels in Code 39 FormatProduct Reference Guide 93Transmit Labels in Code 39 FormatThis feature enable/disables translation
IBM 46XX Interface94 PowerScan® PD7100 CordedNOTES
Product Reference Guide 95Chapter 10Data EditingData Editing OverviewWhen a barcode is scanned, additional information can be sent to the host compute
Data Editing96 PowerScan® PD7100 CordedPlease Keep In Mind...• Modifying a message string is not a mandatory requirement. Data editing is sophisticat
Global Prefix/SuffixProduct Reference Guide 975. If less than the expected string of 20 characters are selected, scan the ENTER/EXIT
Data Editing98 PowerScan® PD7100 CordedGlobal AIM IDAIM label identifiers (as opposed to custom characters you select yourself as with label identifie
Global AIM IDProduct Reference Guide 99Global AIM ID — continuedENTER/EXIT PROGRAMMING MODEGlobal AIM ID = DisableGlobal AIM ID = En
Data Editing100 PowerScan® PD7100 CordedGS1-128 AIM IDIf Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled inde-pendently. The
Label IDProduct Reference Guide 101Label IDA Label ID is a customizable code of up to three ASCII characters (each can be one ofhex
Technical SupportProduct Reference Guide 3Technical SupportDatalogic Website SupportThe Datalogic website (www.scanning.datalogic.co
Data Editing102 PowerScan® PD7100 CordedCODE128 # 230000 T 540000CODE39* 2A0000 V 560000CODE44 340000 4 340000CODE5j 6A0000 j 6A0000CODE93& 260000
Label IDProduct Reference Guide 103Label ID: Set Individually Per SymbologyTo configure a Label ID individually for a single symbolo
Data Editing104 PowerScan® PD7100 CordedLabel ID — continuedTable 18. Label ID ExamplesSTEP ACTION EXAMPLES1. Scan the ENTER/EXIT barcode (Scanner ent
Label IDProduct Reference Guide 105Label ID — continuedLabel ID ControlThis option controls whether a Label ID is disabled, or sent
Data Editing106 PowerScan® PD7100 CordedLabel ID — continuedLabel ID Symbology SelectionThis option selects the symbology for which a Label ID is to b
Label IDProduct Reference Guide 107Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for
Data Editing108 PowerScan® PD7100 CordedLabel ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Labe
Label IDProduct Reference Guide 109Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for
Data Editing110 PowerScan® PD7100 CordedLabel ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for which a Labe
Label IDProduct Reference Guide 111Label ID — continuedLabel ID Symbology Selection — continuedThis option selects the symbology for
Introduction4PowerScan® PD7100 CordedNOTES
Data Editing112 PowerScan® PD7100 CordedCase ConversionThis feature allows conversion of the case of all alphabetic characters to upper or lower case.
Character ConversionProduct Reference Guide 113conversion: BB22BB22.The A characters were converted to B characters and the 1 charac
Data Editing114 PowerScan® PD7100 CordedCharacter Conversion — continuedENTER/EXIT PROGRAMMING MODEConfigure Character ConversionDEFAULT0xFFFFFFFFFFFF
Product Reference Guide 115Chapter 11SymbologiesIntroductionThe reader supports the following symbologies (barcode types). Options for each sym-bology
Symbologies116 PowerScan® PD7100 CordedUPC-AThe following options apply to the UPC-A symbology.UPC-A Enable/DisableWhen disabled, the reader will not
UPC-AProduct Reference Guide 117UPC-A — cont.Expand UPC-A to EAN-13Expands UPC-A data to the EAN-13 data format. Selecting this feat
Symbologies118 PowerScan® PD7100 CordedUPC-A — cont.In-Store Minimum ReadsThis feature specifies the minimum number of consecutive times an in-store l
UPC-EProduct Reference Guide 119UPC-EThe following options apply to the UPC-E symbology.UPC-E Enable/DisableWhen disabled, the reade
Symbologies120 PowerScan® PD7100 CordedUPC-E — cont.Expand UPC-E to EAN-13Expands UPC-E data to the EAN-13 data format. Selecting this feature also ch
UPC-EProduct Reference Guide 121UPC-E — cont.UPC-E Number System Character TransmissionThis feature enables/disables transmission of
Product Reference Guide 5Chapter 2Getting StartedAbout the ReaderAdvancements in the LED technology used in this reader significantly improve the illu
Symbologies122 PowerScan® PD7100 CordedUPC-E — cont.UPC-E Minimum ReadsThis feature specifies the minimum number of consecutive times a UPC-E label mu
GTIN FormattingProduct Reference Guide 123GTIN FormattingThis feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, a
Symbologies124 PowerScan® PD7100 CordedEAN 13The following options apply to the EAN 13 (Jan 13) symbology.EAN 13 Enable/DisableWhen disabled, the read
EAN 13Product Reference Guide 125EAN 13 — cont.EAN-13 Flag 1 CharacterEnables/disables transmission of an EAN/JAN13 Flag1 character.
Symbologies126 PowerScan® PD7100 CordedEAN-13 ISBN ConversionThis option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 97
EAN 13Product Reference Guide 127EAN 13 — cont.EAN 13 Minimum ReadsThis feature specifies the minimum number of consecutive times an
Symbologies128 PowerScan® PD7100 CordedEAN 8The following options apply to the EAN 8 (Jan 8) symbology.EAN 8 Enable/DisableWhen disabled, the reader w
EAN 8Product Reference Guide 129EAN 8 — cont.Expand EAN 8 to EAN 13Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.
Symbologies130 PowerScan® PD7100 CordedEAN 8 — cont.EAN 8 Minimum ReadsThis feature specifies the minimum number of consecutive times an EAN 8 (Jan 8)
UPC/EAN Global SettingsProduct Reference Guide 131UPC/EAN Global SettingsThis section provides configuration settings for UPC-A, UPC
Getting Started6PowerScan® PD7100 CordedSetting Up the ReaderFollow the steps provided in this section to connect and get your reader up and communica
Symbologies132 PowerScan® PD7100 CordedUPC/EAN Global Settings — cont.UPC/EAN Decoding Level — cont.ENTER/EXIT PROGRAMMING MODEUPC/EAN Decoding Level
UPC/EAN Global SettingsProduct Reference Guide 133UPC/EAN Global Settings — cont.UPC/EAN CorrelationWhen correlation is enabled, the
Symbologies134 PowerScan® PD7100 CordedUPC/EAN Global Settings — cont.UPC/EAN Price Weight CheckThis feature enables/disables calculation and verifica
UPC/EAN Global SettingsProduct Reference Guide 135UPC/EAN Global Settings — cont.UPC-A Minimum ReadsThis feature specifies the minim
Symbologies136 PowerScan® PD7100 CordedAdd-OnsThe following features apply to optional add-ons.Optional Add-onsThe reader can be enabled to optionally
Add-OnsProduct Reference Guide 137Add-Ons — cont.Optional Add-ons — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-Ons = Enable P5Opti
Symbologies138 PowerScan® PD7100 CordedAdd-Ons — cont.Optional Add-On TimerThis option sets the time the reader will look for an add-on when an add-on
Add-OnsProduct Reference Guide 139Add-Ons — cont.Optional Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-on Timer = 60m
Symbologies140 PowerScan® PD7100 CordedAdd-Ons — cont.Optional Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional Add-on Timer = 180msOptional Ad
Add-OnsProduct Reference Guide 141Add-Ons — cont.Optional GS1-128 Add-On TimerThis option sets the timer expiration value to read th
Setting Up the ReaderProduct Reference Guide 7Other connection types are described below and illustrated in Figure 2.USB Connection
Symbologies142 PowerScan® PD7100 CordedAdd-Ons — cont.Optional GS1-128 Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional GS1-128 Add-On Timer =
Add-OnsProduct Reference Guide 143Add-Ons — cont.Optional GS1-128 Add-On Timer — cont.ENTER/EXIT PROGRAMMING MODEOptional GS1-128 Ad
Symbologies144 PowerScan® PD7100 CordedAdd-Ons — cont.P2 Add-Ons Minimum ReadsThis feature specifies the minimum number of times a P2 add-on must be r
Add-OnsProduct Reference Guide 145Add-Ons — cont.P5 Add-Ons Minimum ReadsThis feature specifies the minimum number of times a P5 add
Symbologies146 PowerScan® PD7100 CordedAdd-Ons — cont.GS1-128 Add-Ons Minimum ReadsThis feature specifies the minimum number of times an GS1-128 add-o
GS1 DataBar OmnidirectionalProduct Reference Guide 147GS1 DataBar OmnidirectionalThe following options apply to the GS1 DataBar Omni
Symbologies148 PowerScan® PD7100 CordedGS1 DataBar Omnidirectional — cont.GS1 DataBar Omnidirectional Minimum ReadsThis feature specifies the minimum
GS1 DataBar ExpandedProduct Reference Guide 149GS1 DataBar ExpandedThe following options apply to the GS1 DataBar Expanded (formerly
Symbologies150 PowerScan® PD7100 CordedGS1 DataBar Expanded — cont.GS1 DataBar Expanded Minimum ReadsThis feature specifies the minimum number of cons
GS1 DataBar ExpandedProduct Reference Guide 151GS1 DataBar Expanded — cont.GS1 DataBar Expanded Length ControlThis feature specifies
Getting Started8PowerScan® PD7100 CordedUsing the Programming BarcodesThis manual contains feature descriptions and barcodes which allow you to reconf
Symbologies152 PowerScan® PD7100 CordedGS1 DataBar Expanded — cont.GS1 DataBar Expanded Set Length 1This feature specifies one of the barcode lengths
GS1 DataBar ExpandedProduct Reference Guide 153GS1 DataBar Expanded — cont.GS1 DataBar Expanded Set Length 1 — cont.ENTER/EXIT PROGR
Symbologies154 PowerScan® PD7100 CordedGS1 DataBar Expanded — cont.GS1 DataBar Expanded Set Length 2This feature specifies one of the barcode lengths
GS1 DataBar ExpandedProduct Reference Guide 155GS1 DataBar Expanded — cont.GS1 DataBar Expanded Set Length 2 — cont.ENTER/EXIT PROGR
Symbologies156 PowerScan® PD7100 CordedGS1 DataBar LimitedThe following options apply to the GS1 DataBar Limited (formerly RSS Limited) sym-bology.GS1
GS1 DataBar LimitedProduct Reference Guide 157GS1 DataBar Limited — cont.GS1 DataBar Limited Minimum ReadsThis feature specifies the
Symbologies158 PowerScan® PD7100 CordedCode 39The following options apply to the Code 39 symbology.Code 39 Enable/DisableWhen disabled, the reader wil
Code 39Product Reference Guide 159Code 39 — cont.Code 39 Check Character CalculationEnable this option to enables/disables calculati
Symbologies160 PowerScan® PD7100 CordedCode 39 — cont.Code 39 Check Character TransmissionEnable this option to transmit the check character along wit
Code 39Product Reference Guide 161Code 39 — cont.Code 39 Full ASCIIIn Code 39 decoding, this enables/disables the translation of Cod
Resetting the Standard Product DefaultsProduct Reference Guide 9Resetting the Standard Product DefaultsIf you aren’t sure what progr
Symbologies162 PowerScan® PD7100 CordedCode 39 — cont.Code 39 Quiet ZonesThis feature specifies the number of quiet zones for Code 39 labels. Quiet zo
Code 39Product Reference Guide 163Code 39 — cont.Code 39 Minimum ReadsThis feature specifies the minimum number of consecutive times
Symbologies164 PowerScan® PD7100 CordedCode 39 — cont.Code 39 Decoding LevelDecoding Levels are used to configure a barcode symbology decoder to be ve
Code 39Product Reference Guide 165Code 39 — cont.Code 39 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECode 39 Decoding Level = 1
Symbologies166 PowerScan® PD7100 CordedCode 39 — cont.Code 39 Length ControlThis feature specifies either variable length decoding or fixed length dec
Code 39Product Reference Guide 167Code 39 — cont.Code 39 Set Length 1This feature specifies one of the barcode lengths for Code 39 L
Symbologies168 PowerScan® PD7100 CordedCode 39 — cont.Code 39 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 39 Set Length 1 SettingMake a
Code 39Product Reference Guide 169Code 39 — cont.Code 39 Set Length 2This feature specifies one of the barcode lengths for Code 39 L
Symbologies170 PowerScan® PD7100 CordedCode 39 — cont.Code 39 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 39Length 2 SettingMake a mist
Code 39Product Reference Guide 171Code 39 — cont.Code 39 Interdigit RatioThis feature specifies the ratio between an intercharacter
Getting Started10 PowerScan® PD7100 CordedNOTES
Symbologies172 PowerScan® PD7100 CordedCode 39 — cont.Code 39 Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECode 39 Interdigit Ratio = 6Code 39 I
Code 39Product Reference Guide 173Code 39 — cont.Code 39 Character CorrelationWhen correlation is enabled, the barcode reader will c
Symbologies174 PowerScan® PD7100 CordedCode 39 StitchingThis option enables/disables stitching for Code 39 labels. When parts of a Code 39 bar-code ar
Code 32Product Reference Guide 175Code 32The following options apply to the Code 32 (Italian Pharamaceutical Code) symbology.Code 32
Symbologies176 PowerScan® PD7100 CordedCode 32 — cont.Code 32 Check Character TransmissionEnable this option to transmit the check character along wit
Code 128Product Reference Guide 177Code 128The following options apply to the Code 128 symbology.Code 128 Enable/DisableWhen disable
Symbologies178 PowerScan® PD7100 CordedCode 128 — cont.Code 128 Check Character TransmissionEnable this option to transmit the check character along w
Code 128Product Reference Guide 179Code 128 — cont.Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-C
Symbologies180 PowerScan® PD7100 CordedCode 128 — cont.Code 128 Quiet ZonesThis feature specifies the number of quiet zones for Code 128 labels. Quiet
Code 128Product Reference Guide 181Code 128 — cont.Code 128 Minimum ReadsThis feature specifies the minimum number of consecutive ti
Product Reference Guide 11Chapter 3InterfacesInterface SelectionEach reader model will support one of the following sets of host interfaces:General Pu
Symbologies182 PowerScan® PD7100 CordedCode 128 — cont.Code 128 Decoding LevelDecoding Levels are used to configure a barcode symbology decoder to be
Code 128Product Reference Guide 183Code 128 — cont.Code 128 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECode 128 Decoding Level
Symbologies184 PowerScan® PD7100 CordedCode 128 — cont.Code 128 Length ControlThis feature specifies either variable length decoding or fixed length d
Code 128Product Reference Guide 185Code 128 — cont.Code 128 Set Length 1This feature specifies one of the barcode lengths for Code 1
Symbologies186 PowerScan® PD7100 CordedCode 128 — cont.Code 128 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 128 Set Length 1 SettingMak
Code 128Product Reference Guide 187Code 128 — cont.Code 128 Set Length 2This feature specifies one of the barcode lengths for Code 1
Symbologies188 PowerScan® PD7100 CordedCode 128 — cont.Code 128 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 128 Length 2 SettingMake a
Code 128Product Reference Guide 189Code 128 — cont.Code 128 Character CorrelationWhen correlation is enabled, the barcode reader wil
Symbologies190 PowerScan® PD7100 CordedCode 128 — cont.Code 128 StitchingThis option enables/disables stitching for Code 128 labels. When parts of a C
GS1-128Product Reference Guide 191GS1-128The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC
Datalogic Scanning, Inc.959 Terry StreetEugene, Oregon 97402Telephone: (541) 683-5700Fax: (541) 345-7140An Unpublished Work - All rights reserved. No
Interfaces12 PowerScan® PD7100 CordedTable 1. Available InterfacesRS-232 FEATURESRS-232 standard interfaceSelect RS232-STDSet RS-232 InterfaceFeatures
Symbologies192 PowerScan® PD7100 CordedInterleaved 2 of 5 (I 2 of 5)The following options apply to the I 2 of 5 symbology.I 2 of 5 Enable/DisableWhen
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 193Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Check Character CalculationThi
Symbologies194 PowerScan® PD7100 CordedInterleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Check Character TransmissionEnable this option to transmit the ch
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 195Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Minimum ReadsThis feature spec
Symbologies196 PowerScan® PD7100 CordedInterleaved 2 of 5 (I 2 of 5) — cont.2 of 5 Decoding LevelDecoding Levels are used to configure a barcode symbo
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 197Interleaved 2 of 5 (I 2 of 5) — cont.2 of 5 Decoding Level — cont.ENTER/EXIT
Symbologies198 PowerScan® PD7100 CordedInterleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Length ControlThis feature specifies either variable length decod
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 199Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 1This feature speci
Symbologies200 PowerScan® PD7100 CordedInterleaved 2 of 5 (I 2 of 5) — cont.Datalogic 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect I 2
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 201Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 2This feature speci
Configuring the InterfaceProduct Reference Guide 13KEYBOARD FEATURESAT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95w/Stand
Symbologies202 PowerScan® PD7100 CordedInterleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect I 2 of 5 Le
Interleaved 2 of 5 (I 2 of 5)Product Reference Guide 203Interleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 Character CorrelationWhen corr
Symbologies204 PowerScan® PD7100 CordedInterleaved 2 of 5 (I 2 of 5) — cont.I 2 of 5 StitchingThis option enables/disables stitching for I 2 of 5 labe
Datalogic 2 of 5Product Reference Guide 205Datalogic 2 of 5The following options apply to the Datalogic 2 of 5 symbology.Datalogic 2
Symbologies206 PowerScan® PD7100 CordedDatalogic 2 of 5 — cont.Datalogic 2 of 5 Check Character CalculationThis option enables/disables calculation an
Datalogic 2 of 5Product Reference Guide 207Datalogic 2 of 5 — cont.Datalogic 2 of 5 Minimum ReadsThis feature specifies the minimum
Symbologies208 PowerScan® PD7100 CordedDatalogic 2 of 5 — cont.Datalogic 2 of 5 Length ControlThis feature specifies either variable length decoding o
Datalogic 2 of 5Product Reference Guide 209Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 1This feature specifies one of the ba
Symbologies210 PowerScan® PD7100 CordedDatalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Datalogic 2 of 5
Datalogic 2 of 5Product Reference Guide 211Datalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 2This feature specifies one of the ba
Interfaces14 PowerScan® PD7100 CordedKEYBOARD — cont. FEATURESKeyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboardSelect KBD-IBM
Symbologies212 PowerScan® PD7100 CordedDatalogic 2 of 5 — cont.Datalogic 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Datalogic 2 of 5
Datalogic 2 of 5Product Reference Guide 213Datalogic 2 of 5 — cont.Datalogic 2 of 5 Interdigit Maximum RatioThis feature specifies t
Symbologies214 PowerScan® PD7100 CordedDatalogic 2 of 5 Interdigit Maximum Ratio — cont.Datalogic 2 of 5 Interdigit Maximum Ratio = 6Datalogic 2 of 5
Datalogic 2 of 5Product Reference Guide 215Datalogic 2 of 5 — cont.Datalogic 2 of 5 Character CorrelationWhen correlation is enabled
Symbologies216 PowerScan® PD7100 CordedDatalogic 2 of 5 — cont.Datalogic 2 of 5 StitchingThis option enables/disables stitching for Datalogic 2 of 5 l
CodabarProduct Reference Guide 217CodabarThe following options apply to the Codabar symbology.Codabar Enable/DisableWhen disabled, t
Symbologies218 PowerScan® PD7100 CordedCodabar — cont.Codabar Check Character CalculationEnable this option to enables/disables calculation and verifi
CodabarProduct Reference Guide 219Codabar — cont.Codabar Check Character TransmissionEnable this option to transmit the check charac
Symbologies220 PowerScan® PD7100 CordedCodabar — cont.Codabar Start/Stop Character SetThis option specifies the format of transmitted Codabar start/st
CodabarProduct Reference Guide 221Codabar — cont.Codabar Start/Stop Character MatchWhen enabled, this option requires that start and
Global Interface FeaturesProduct Reference Guide 15Global Interface FeaturesThe following interface features are configurable by all
Symbologies222 PowerScan® PD7100 CordedCodabar — cont.Codabar Quiet ZonesThis feature specifies the number of quiet zones for Codabar labels. Quiet zo
CodabarProduct Reference Guide 223Codabar — cont.Codabar Minimum ReadsThis feature specifies the minimum number of consecutive times
Symbologies224 PowerScan® PD7100 CordedCodabar — cont.Codabar Decoding LevelDecoding Levels are used to configure a barcode symbology decoder to be ve
CodabarProduct Reference Guide 225Codabar — cont.Codabar Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECodabar Decoding Level = 1
Symbologies226 PowerScan® PD7100 CordedCodabar — cont.Codabar Length ControlThis feature specifies either variable length decoding or fixed length dec
CodabarProduct Reference Guide 227Codabar — cont.Codabar Set Length 1This feature specifies one of the barcode lengths for Codabar L
Symbologies228 PowerScan® PD7100 CordedCodabar — cont.Codabar Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Codabar Length 1 SettingMake a mis
CodabarProduct Reference Guide 229Codabar — cont.Codabar Set Length 2This feature specifies one of the barcode lengths for Codabar L
Symbologies230 PowerScan® PD7100 CordedCodabar — cont.Codabar Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect CodabarLength 2 SettingMake a mist
CodabarProduct Reference Guide 231Codabar — cont.Codabar Interdigit RatioThis feature specifies the ratio between an intercharacter
Interfaces16 PowerScan® PD7100 CordedUSB Suspend Mode This setting enables/disables the ability of USB interfaces to enter suspend mode.ENTER/EXIT PRO
Symbologies232 PowerScan® PD7100 CordedCodabar — cont.Codabar Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECodabar Interdigit Ratio = 6Codabar I
CodabarProduct Reference Guide 233Codabar — cont.Codabar Character CorrelationWhen correlation is enabled, the barcode reader will c
Symbologies234 PowerScan® PD7100 CordedCodabar StitchingThis option enables/disables stitching for Codabar labels. When parts of a Codabar bar-code ar
Code 11Product Reference Guide 235Code 11The following options apply to the Code 11 symbology.Code 11 Enable/DisableWhen disabled, t
Symbologies236 PowerScan® PD7100 CordedCode 11 — cont.Code 11 Check Character CalculationThis option enables/disables calculation and verification of
Code 11Product Reference Guide 237Code 11 — cont.Code 11 Check Character TransmissionThis feature enables/disables transmission of a
Symbologies238 PowerScan® PD7100 CordedCode 11 — cont.Code 11 Minimum ReadsThis feature specifies the minimum number of consecutive times a Code 93 la
Code 11Product Reference Guide 239Code 11 — cont.Code 11 Length ControlThis feature specifies either variable length decoding or fix
Symbologies240 PowerScan® PD7100 CordedCode 11 — cont.Code 11 Set Length 1This feature specifies one of the barcode lengths for Code 11 Length Control
Code 11Product Reference Guide 241Code 11 — cont.Code 11 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 11 Set Length 1
Product Reference Guide 17Chapter 4General FeaturesDouble Read TimeoutTo prevent a double read of the same label, the Double Read Timeout sets the min
Symbologies242 PowerScan® PD7100 CordedCode 11 — cont.Code 11 Set Length 2This feature specifies one of the barcode lengths for Code 11 Length Control
Code 11Product Reference Guide 243Code 11 — cont.Code 11 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESelect Code 11 Length 2 Sett
Symbologies244 PowerScan® PD7100 CordedCode 11 — cont.Code 11 Interdigit RatioThis feature specifies the ratio between an intercharacter space and mod
Code 11Product Reference Guide 245Code 11 — cont.Code 11 Interdigit Ratio — cont.ENTER/EXIT PROGRAMMING MODECode 11 Interdigit Ratio
Symbologies246 PowerScan® PD7100 CordedCode 11 Decoding LevelDecoding Levels are used to configure a barcode symbology decoder to be very aggressive t
Code 11Product Reference Guide 247Code 11 — cont.Code 11 Decoding Level — cont.ENTER/EXIT PROGRAMMING MODECodabar Decoding Level = 1
Symbologies248 PowerScan® PD7100 CordedCode 11 — cont.Code 11 Character CorrelationWhen correlation is enabled, the barcode reader will combine label
Code 11Product Reference Guide 249Code 11 StitchingThis option enables/disables stitching for Code 11 labels. When parts of a Code 1
Symbologies250 PowerScan® PD7100 CordedStandard 2 of 5The following options apply to the Standard 2 of 5 symbology.Standard 2 of 5 Enable/DisableWhen
Standard 2 of 5Product Reference Guide 251Standard 2 of 5 — cont.Standard 2 of 5 Check Character CalculationThis option enables/disa
General Features18 PowerScan® PD7100 CordedDouble Read Timeout — continuedENTER/EXIT PROGRAMMING MODEDouble Read Timeout = 0.5 SecondDouble Read Timeo
Symbologies252 PowerScan® PD7100 CordedStandard 2 of 5 — cont.Standard 2 of 5 Minimum ReadsThis feature specifies the minimum number of consecutive ti
Standard 2 of 5Product Reference Guide 253Standard 2 of 5 — cont.Standard 2 of 5 Length ControlThis feature specifies either variabl
Symbologies254 PowerScan® PD7100 CordedStandard 2 of 5 — cont.Standard 2 of 5 Set Length 1This feature specifies one of the barcode lengths for Standa
Standard 2 of 5Product Reference Guide 255Standard 2 of 5 — cont.Standard 2 of 5 Set Length 1 — cont.ENTER/EXIT PROGRAMMING MODESele
Symbologies256 PowerScan® PD7100 CordedStandard 2 of 5 — cont.Standard 2 of 5 Set Length 2This feature specifies one of the barcode lengths for Standa
Standard 2 of 5Product Reference Guide 257Standard 2 of 5 — cont.Standard 2 of 5 Set Length 2 — cont.ENTER/EXIT PROGRAMMING MODESele
Symbologies258 PowerScan® PD7100 CordedStandard 2 of 5 — cont.Standard 2 of 5 Character CorrelationWhen correlation is enabled, the barcode reader wil
Standard 2 of 5Product Reference Guide 259Standard 2 of 5 StitchingThis option enables/disables stitching for Standard 2 of 5 labels
Symbologies260 PowerScan® PD7100 CordedISBT 128The following options apply to the ISBT 128 symbology.ISBT 128 Enable/DisableWhen disabled, the imager
ISBT 128Product Reference Guide 261ISBT 128 — cont.ISBT 128 Force ConcatenationWhen enabled, this feature forces concatenation for I
Label Gone TimeoutProduct Reference Guide 19Label Gone TimeoutThis feature sets the time after the last label segment is seen before
Symbologies262 PowerScan® PD7100 CordedCode 4The following options apply to the Code 4 symbology.Code 4 Enable/DisableEnables/Disables ability of imag
Code 4Product Reference Guide 263Code 4 — cont.Code 4 Check Character TransmissionThis feature enables/disables transmission of an o
Symbologies264 PowerScan® PD7100 CordedCode 5The following options apply to the Code 5 symbology.Code 5 Enable/DisableEnables/Disables ability of imag
Code 5Product Reference Guide 265Code 5 — cont.Code 5 Check Character TransmissionThis feature enables/disables transmission of an o
Symbologies266 PowerScan® PD7100 CordedCode 4 and Code 5 Common Configuration ItemsThe following options apply to both Code 4 and Code 5 symbologies.C
Code 4 and Code 5 Common Configuration ItemsProduct Reference Guide 267Code 4 and Code 5 Common Configuration Items — cont.Code 4 an
Symbologies268 PowerScan® PD7100 CordedCode 4 and Code 5 Common Configuration Items — cont.Code 4 and Code 5 Minimum ReadsThis feature specifies the m
Follett 2 of 5Product Reference Guide 269Follett 2 of 5The following options apply to the Follett 2 of 5 symbology.Follett 2 of 5 En
Symbologies270 PowerScan® PD7100 CordedNOTES
Product Reference Guide 271Appendix ATechnical SpecificationsTable 35 contains Physical and Performance Characteristics, User Environment and Regulato
General Features20 PowerScan® PD7100 CordedLabel Gone Timeout — cont.ENTER/EXIT PROGRAMMING MODESelect Label Gone Timeout SettingMake a mistake? Scan
272 PowerScan® PD7100 CordedMinimum Element Width 3 milPrint Contrast Minimum 15% minimum reflectanceDecode CapabilityUPC/EAN/JAN, P2 /P5 add-ons; Cod
Standard Cable PinoutsProduct Reference Guide 273Standard Cable PinoutsFigure 7 and Table 36 provide standard pinout information for
274 PowerScan® PD7100 CordedNOTES
Product Reference Guide 275Appendix BStandard DefaultsThe most common configuration settings are listed in the “Default” column of Table 37.The settin
276 PowerScan® PD7100 CordedLaser Pointer ControlStart scanning imme-diately after trigger42Laser Pointer Period500 ms43Green Spot Duration300 ms45RS-
Product Reference Guide 277USB Keyboard Speed1 ms85USB-OEMUSB-OEM Device UsageHandheld Scanner88Data EditingGlobal Prefix/SuffixNo G
278 PowerScan® PD7100 CordedEAN 13EAN 13 Enable/DisableEnable124EAN 13 Check Character TransmissionSend124EAN-13 Flag 1 CharacterTra n sm it125EAN-13
Product Reference Guide 279GS1 DataBar ExpandedGS1 DataBar Expanded Enable/DisableDisable149GS1 DataBar Expanded GS1-128 Emula-tionD
280 PowerScan® PD7100 CordedCode 32 Feature Setting Exceptions3175Code 32 Check Character TransmissionDon’t Send176Code 32 Start/Stop Character Transm
Product Reference Guide 281Datalogic 2 of 5Datalogic 2 of 5 Enable/DisableEnable205Datalogic 2 of 5 Check Character Calcu-lationDisa
Sleep Mode TimeoutProduct Reference Guide 21Sleep Mode TimeoutSpecifies the timeout value for the reader to enter low power Sleep Mo
282 PowerScan® PD7100 CordedCode 11 Check Character CalculationCheck C and K236Code 11 Check Character TransmissionSend237Code 11 Minimum Reads1238Cod
Product Reference Guide 283Code 4 Hex to Decimal ConversionEnable263Code 5Code 5 Enable/DisableDisable264Code 5 Check Character Tran
284 PowerScan® PD7100 CordedDefault ExceptionsTable 37 lists standard default settings as applied to a standard RS-232 interface. Table 38 provides a
Default ExceptionsProduct Reference Guide 285EAN8/P2 Label ID Character(s) BEAN8/P5 Label ID Character(s) BEAN8/GS1-128 Label ID Cha
286 PowerScan® PD7100 CordedUPCE/P5 Label ID Character(s) IEAN8/P2 Label ID Character(s) JEAN8/P5 Label ID Character(s) KEAN8/GS1-128 Label ID Charact
Product Reference Guide 287Appendix CLED and Beeper IndicationsThe reader’s beeper sounds and its LED illuminates to indicate various functions or err
288 PowerScan® PD7100 CordedLED and Beeper IndicationsINDICATION DESCRIPTION LED BEEPERPower-up BeepThe reader is in the process of pow-ering-up.Reade
Error CodesProduct Reference Guide 289Error CodesUpon startup, if the reader sounds a long tone, this means the reader has not passe
290 PowerScan® PD7100 CordedNOTES
Product Reference Guide 291Appendix DSample BarcodesThe sample barcodes in this appendix are typical representations for their symbology types. UP
Product Reference Guide1Table of ContentsChapter 1. Introduction...
General Features22 PowerScan® PD7100 CordedSleep Mode Timeout — continuedENTER/EXIT PROGRAMMING MODESleep Mode Timeout = 5 SecondsSleep Mode Timeout =
292 PowerScan® PD7100 CordedSample Barcodes — continuedCode 32 CodabarCode 93 Code 11
GS1 DataBar (RSS)Product Reference Guide 293GS1 DataBar (RSS)GS1 DataBar-14NOTEGS1 DataBar variants must be enabled to read the barc
294 PowerScan® PD7100 CordedNOTES
Product Reference Guide 295Appendix EKeypadUse the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad.0123
296 PowerScan® PD7100 Corded6789ABC
Product Reference Guide 297DEF
298 PowerScan® PD7100 CordedNOTES
Product Reference Guide 299Appendix FScancode TablesControl Character EmulationControl character emulation selects from different scancode tables as l
Product Reference Guide 300Interface Type PC AT PS/2 or USB-KeyboardTable 39. Scancode Set When Control Character is 00 or 01Extended characters (sk
Product Reference Guide 301Interface Type PC AT PS/2 or USB-Keyboard — cont.Table 40. Scancode Set When Control Character is 02x0 x1 x2 x3 x4 x5 X6 x7
LED and Beeper IndicatorsProduct Reference Guide 23LED and Beeper IndicatorsPower On AlertDisables or enables the indication (from t
Product Reference Guide 302Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt ModeTable 41. Scancode Set When Control Character is 00 or 01x0 x1
Product Reference Guide 303Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont.Table 42. Scancode Set When Control Character is 02x0 x1
Product Reference Guide 304Digital InterfaceTable 43. Scancode Set When Control Character is 00 or 01X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
Product Reference Guide 305Digital Interface — cont.Table 44. Scancode Set When Control Character is 02X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
Product Reference Guide 306IBM31xx 102-keyTable 45. Scancode Set When Control Character is 00 or 01X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0
Product Reference Guide 307IBM31xx 102-key — cont.Table 46. Scancode Set When Control Character is 02X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0x
Product Reference Guide 308IBM XTTable 47. Scancode Set When Control Character is 00 or 01X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xNULLC(S)+
Product Reference Guide 309IBM XT — cont.Table 48. Scancode Set When Control Character is 02X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF0xArÈ ArÇ A
310 PowerScan® PD7100 CordedMicrosoft Windows Codepage 1252Windows-1252 is a character encoding of the Latin alphabet, used by default in the leg-acy
Microsoft Windows Codepage 1252Product Reference Guide 311NOTES
General Features24 PowerScan® PD7100 CordedGood Read: When to IndicateThis feature specifies when the reader will provide indication (beep and/or flas
312 PowerScan® PD7100 CordedNOTES
Product Reference Guide313IndexAAmbient Light Immunity 272Bbar codesRS-232baud rate 85RS-232 parametersparity 260, 262, 264, 267, 269barcodescancel 29
314 PowerScan® 7100 CordedLLight Source 271MMixed OEM Standard + Code 39 For-mat 93Nnumbers lock key 77OOperating Temperature 272PPerformance Characte
ASCII ChartASCIIChar.Hex No.ASCIIChar.Hex No.ASCIIChar.Hex No.ASCIIChar.HexNo.NULSOHSTXETXEOTENQACKBELBSHTLFVTFFCRSOSIDLEDC1DC2DC3DC4NAKSYNETBCANEMSUB
AustraliaDatalogic Scanning Pty LtdTelephone: [61] (2) 9870 [email protected] and BeneluxDatalogic Scanning SarlTelephone: [3
LED and Beeper IndicatorsProduct Reference Guide 25Good Read Beep TypeSpecifies whether the good read beep has a mono or bitonal bee
General Features26 PowerScan® PD7100 CordedGood Read Beep FrequencyAdjusts the good read beep to sound at a selectable low, medium or high frequency,
LED and Beeper IndicatorsProduct Reference Guide 27Good Read Beep Length — continuedENTER/EXIT PROGRAMMING MODEGood Read Beep Length
General Features28 PowerScan® PD7100 CordedGood Read Beep VolumeSelects the beeper volume (loudness) upon a good read beep. There are three selectable
LED and Beeper IndicatorsProduct Reference Guide 29Good Read LED DurationThis feature specifies the amount of time that the Good Rea
General Features30 PowerScan® PD7100 CordedGood Read LED Duration — cont.ENTER/EXIT PROGRAMMING MODESelect Good Read LED Duration SettingMake a mistak
Scanning FeaturesProduct Reference Guide 31Scanning FeaturesScan ModeSelects the scan operating mode for the reader. Selections are:
2PowerScan® PD7100 CordedChapter 5. RS-232 ONLY Interface...
General Features32 PowerScan® PD7100 CordedScan Mode — continuedENTER/EXIT PROGRAMMING MODEScan Mode = Trigger SingleScan Mode = Trigger Hold Multiple
Scanning FeaturesProduct Reference Guide 33Stand Mode Triggered TimeoutThis feature specifies the time to remain in Trigger Single m
General Features34 PowerScan® PD7100 CordedStand Mode Triggered Timeout — continuedENTER/EXIT PROGRAMMING MODEStand Mode Triggered Timeout = 6 Seconds
Scanning FeaturesProduct Reference Guide 35Scanning Active TimeThis setting specifies the amount of time that the reader stays in sc
General Features36 PowerScan® PD7100 CordedScanning Active Time — cont.ENTER/EXIT PROGRAMMING MODESelect Scanning Active Time SettingMake a mistake? S
Flash On TimeProduct Reference Guide 37Flash On TimeThis feature specifies the ON time for the indicator LED while in Flash Mode. Th
General Features38 PowerScan® PD7100 CordedFlash On Time — cont.ENTER/EXIT PROGRAMMING MODESelect Flash ON Time SettingMake a mistake? Scan the CANCEL
Flash Off TimeProduct Reference Guide 39Flash Off TimeThis feature specifies the OFF time for the indicator LED while in Flash Mode.
General Features40 PowerScan® PD7100 CordedFlash Off Time — cont.ENTER/EXIT PROGRAMMING MODESelect Flash OFF Time SettingMake a mistake? Scan the CANC
Stand Mode SensitivityProduct Reference Guide 41Stand Mode SensitivitySets the sensitivity level for stand mode wakeup. Choices are
Product Reference Guide3Label ID Control ...
General Features42 PowerScan® PD7100 CordedLaser Pointer ControlSpecifies the amount of time that the laser pointer is turned on preliminary to scanni
Laser Pointer PeriodProduct Reference Guide 43Laser Pointer PeriodThis option specifies the period of the laser pointer blink during
General Features44 PowerScan® PD7100 CordedLaser Pointer Period — cont.Laser Pointer Period = 2.5 Seconds (2,500 ms)Laser Pointer Period = 3 Seconds
Green Spot DurationProduct Reference Guide 45Green Spot DurationSpecifies the duration of the good read pointer beam after a good re
General Features46 PowerScan® PD7100 CordedNOTES
Product Reference Guide 47Chapter 5RS-232 ONLY InterfaceIntroductionUse the programming barcodes in this chapter if modifications to the standard RS-2
RS-232 ONLY Interface48 PowerScan® PD7100 CordedBaud Rate — continuedENTER/EXIT PROGRAMMING MODEBaud Rate = 9600Baud Rate = 19,200Baud Rate = 38,400Ba
Data BitsProduct Reference Guide 49Data BitsThis parameter allows the reader to interface with devices requiring a 7-bit or 8-bit AS
RS-232 ONLY Interface50 PowerScan® PD7100 CordedStop BitsThe stop bit(s) at the end of each transmitted character marks the end of transmission of one
ParityProduct Reference Guide 51ParityThis feature specifies parity required for sending and receiving data. A parity check bit is t
4PowerScan® PD7100 CordedGS1 DataBar Limited Enable/Disable ... 156GS1 Da
RS-232 ONLY Interface52 PowerScan® PD7100 CordedHandshaking ControlThe data interface consists of an RS-232 port designed to operate either with or wi
Product Reference Guide 53Chapter 6RS-232/USB-Com InterfacesIntroductionThe programming barcodes in this chapter allow modifications to the standard R
RS-232/USB-Com Interfaces54 PowerScan® PD7100 CordedIntercharacter DelayThis parameter specifies the intercharacter delay between the end of one chara
Intercharacter DelayProduct Reference Guide 55Intercharacter Delay — cont.ENTER/EXIT PROGRAMMING MODEIntercharacter Delay = No Delay
RS-232/USB-Com Interfaces56 PowerScan® PD7100 CordedBeep On ASCII BELWhen this parameter is enabled, the reader issues a beep when a <BEL> chara
ACK NAK OptionsProduct Reference Guide 57ACK NAK OptionsThis enables/disables the ability of the reader to support the RS-232 ACK/NA
RS-232/USB-Com Interfaces58 PowerScan® PD7100 CordedACK CharacterThis setting specifies an ASCII character or hex value to be used as the ACK charac-t
ACK NAK OptionsProduct Reference Guide 59ACK Character — cont.ENTER/EXIT PROGRAMMING MODESelect ACK Character SettingDEFAULT0x06 ‘AC
RS-232/USB-Com Interfaces60 PowerScan® PD7100 CordedNAK CharacterThis setting specifies an ASCII character or hex value to be used as the NAK charac-t
ACK NAK OptionsProduct Reference Guide 61NAK Character — cont.ENTER/EXIT PROGRAMMING MODESelect NAK Character SettingDEFAULT0x15 ‘NA
Product Reference Guide5Datalogic 2 of 5 Stitching ... 21
RS-232/USB-Com Interfaces62 PowerScan® PD7100 CordedACK NAK Timeout ValueThis option specifies the amount of time the reader waits for an ACK characte
ACK NAK OptionsProduct Reference Guide 63ACK NAK Timeout Value — cont.ENTER/EXIT PROGRAMMING MODESelect ACK NAK Timeout Value Settin
RS-232/USB-Com Interfaces64 PowerScan® PD7100 CordedACK NAK Retry CountThis feature specifies the number of times the reader retries a label transmiss
ACK NAK OptionsProduct Reference Guide 65ACK NAK Retry Count — cont.ENTER/EXIT PROGRAMMING MODESelect ACK NAK Retry Count SettingMak
RS-232/USB-Com Interfaces66 PowerScan® PD7100 CordedACK NAK Error HandlingThis feature specifies the method the reader uses to handle receive errors d
Indicate Transmission FailureProduct Reference Guide 67Indicate Transmission FailureThis option enables/disables the reader’s abilit
RS-232/USB-Com Interfaces68 PowerScan® PD7100 CordedDisable CharacterSpecifies the value of the RS-232 host command used to disable the reader.ASCII c
Disable CharacterProduct Reference Guide 69Disable Character — cont.ENTER/EXIT PROGRAMMING MODESelect Disable Character SettingDEFAU
RS-232/USB-Com Interfaces70 PowerScan® PD7100 CordedEnable CharacterSpecifies the value of the RS-232 host command used to enable the reader.ASCII cha
Enable CharacterProduct Reference Guide 71Enable Character — cont.ENTER/EXIT PROGRAMMING MODESelect Enable Character SettingDEFAULT0
6PowerScan® PD7100 CordedAppendix A. Technical Specifications ... 2
RS-232/USB-Com Interfaces72 PowerScan® PD7100 CordedNOTES
Product Reference Guide 73Chapter 7Keyboard InterfaceIntroductionUse the programming barcodes in this chapter to select options for USB Keyboard and W
Keyboard Interface74 PowerScan® PD7100 CordedCountry ModeThis feature specifies the country/language supported by the keyboard.Only the following inte
Country ModeProduct Reference Guide 75Country Mode — continuedENTER/EXIT PROGRAMMING MODECountry Mode = DenmarkSupports only the int
Keyboard Interface76 PowerScan® PD7100 CordedCountry Mode — continuedENTER/EXIT PROGRAMMING MODECountry Mode = PolandSupports only the interfaces list
Caps Lock StateProduct Reference Guide 77Caps Lock StateThis option specifies the format in which the reader sends character data. T
Keyboard Interface78 PowerScan® PD7100 CordedSend Control CharactersThis feature Specifies how the reader transmits ASCII control characters to the ho
Wedge Quiet IntervalProduct Reference Guide 79Wedge Quiet IntervalThis option specifies the amount of time to look for keyboard acti
Keyboard Interface80 PowerScan® PD7100 CordedWedge Quiet Interval — cont.ENTER/EXIT PROGRAMMING MODESelect Wedge Quiet Interval SettingMake a mistake?
Intercharacter DelayProduct Reference Guide 81Intercharacter DelayThis parameter specifies the intercharacter delay between the end
Product Reference Guide 1Chapter 1IntroductionAbout this GuideThis Product Reference Guide (PRG) is provided for users seeking advanced technical info
Keyboard Interface82 PowerScan® PD7100 CordedIntercharacter Delay — cont.ENTER/EXIT PROGRAMMING MODEIntercharacter Delay = No DelaySelect Intercharact
Intercode DelayProduct Reference Guide 83Intercode DelaySpecifies the delay between labels transmitted to the host for this interfac
Keyboard Interface84 PowerScan® PD7100 CordedIntercode Delay — cont.ENTER/EXIT PROGRAMMING MODESet Intercode DelayMake a mistake? Scan the CANCEL barc
USB Keyboard SpeedProduct Reference Guide 85USB Keyboard SpeedThis option specifies the USB poll rate for a USB keyboard.NOTEThis fe
Keyboard Interface86 PowerScan® PD7100 CordedUSB Keyboard Speed — continuedENTER/EXIT PROGRAMMING MODEUSB Keyboard Speed = 6msUSB Keyboard Speed = 7ms
Product Reference Guide 87Chapter 8USB-OEM InterfaceIntroductionFeature settings for USB interfaces differ depending upon which host type the reader w
USB-OEM Interface88 PowerScan® PD7100 CordedUSB-OEM Device UsageThe USB-OEM protocol allows for the reader to be identified as one of two different ty
Product Reference Guide 89Chapter 9IBM 46XX InterfaceIntroductionUse the barcodes in this section to configure programmable features for available IBM
IBM 46XX Interface90 PowerScan® PD7100 Corded46xx Number of Host ResetsSpecifies how many consecutive resets are processed before the reader starts a
46xx Number of Host ResetsProduct Reference Guide 9146xx Number of Host Resets — cont.ENTER/EXIT PROGRAMMING MODE46xx Number of Host